Seven major causes of insufficient power for diesel generators

Weifang, Shandong generator power is insufficient, or the diesel engine automatically shuts down after working for a period of time. This is likely to be a malfunction of the generator's fuel system. If you want to solve the problem in time, you need to know the specific reason.

1. Oil leakage of fuel injection pump plunger and oil outlet valve, low supply pressure of fuel injection pump, insufficient oil supply;

2. Insufficient atomization of fuel injector, drip oil, damage of fuel injector, or improper thickness of copper seal of injector;

3. The low pressure of the fuel low pressure oil line is mainly due to the fact that the check valve of the low pressure oil return screw of the fuel injection pump is not tightly closed or has been damaged, which leads to its poor sealing;

4, the oil pump is damaged, fuel pre-pressure is too low;

5, there is a problem with the fuel pump speed regulator;

6. The fuel oil is blocked or the air in the fuel oil system enters;

7. The fuel filter element is too dirty or the fuel temperature is too high. This is the reason why the diesel generator set introduced to the user is insufficiently powered. The user should use these reasons to use the diesel generator set to prevent the unit from providing power failure.

Medical Casters

Medical Caster Wheels,Medical Casters,Medici Cast,Hospital Bed Castors

Yangjiang Xingyang Industry & Trade Co.,Ltd. , https://www.xycaster.com

Posted on